Back to blog

Field notes24 August 2026

How we taught a robot 100% coverage in helium leak testing

How brazed joints once checked by hand with a sniffer came to be tested without exception, using two KUKAs and a 3D camera. And why the hardest part was not the robot, but the way the product sits in the jig.

Simbiosis Engineering Team7 min read

GOLDEN SAMPLE · POINT LISTFIXED COORDINATES · POINTS MISS3D SCAN · Δx · Δy · θLIST FITTED TO THE UNIT · 100% COVERAGE
01/04Golden sample

An air conditioner’s outdoor unit has dozens of brazed joints, and every one of them is a potential refrigerant leak. In the factory, these joints were checked by hand with a helium sniffer. On a good day the operator covers them all; when tired, at the end of a shift, or when the line is running fast that day, some get missed. A missed joint shows up in the field, in the customer’s home. Service calls, returns, reputation. The question put to us was simple: couldn’t a robot do this?

It could. But the robot was the easiest part of the project.

of brazed joints tested
0%of brazed joints tested
KUKAs working in parallel
0KUKAs working in parallel
test stations, one rail
0test stations, one rail
product models
0+product models
01

The real problem: no two products sit in the jig the same way

In the first weeks we tried the classic approach: teach the robot each model’s brazed joints, then visit them in turn as each product arrives. Perfect on paper. On the shop floor, though, products sit in the jig a few millimetres off; the tube bundle is slightly tilted, the body has shifted a touch. A detector tip working to fixed coordinates either hits a tube or passes two centimetres wide of the joint. A helium detector needs no contact, but it won’t read correctly from a centimetre away either. Our tolerance was in the order of millimetres.

The solution came in two parts. First, for each model we chose a “golden sample” and carefully defined the coordinates of its brazed joints on it, once. Then we scanned every product arriving on the line with a 3D camera and measured its offset against the golden sample: shift in three axes, slight rotation. The robot adapts the whole point list to that product using this offset. The golden sample is defined once; every product brings its own correction with it.

The golden sample and the offset

01 / 04

Golden sample

Each model’s brazed joints are defined once, on a carefully chosen product.

02 / 04

Incoming product

The product on the line sits in the jig a few millimetres off and slightly rotated. A tip working to fixed coordinates misses the joint.

03 / 04

3D scan

The camera scans the product and measures its offset against the golden sample: shift in three axes, slight rotation.

04 / 04

Corrected list

The whole point list is adapted to that product with this offset. Every product brings its own correction.

02

Why two robots?

Cycle time. Covering every joint with a single arm took longer than the line’s takt. We put two KUKAs on one carriage, which travels between three stations on a 7th-axis rail we designed ourselves. With both arms working simultaneously, scan time was cut practically in half. The price was getting zone sharing and synchronisation right from the start, so the two arms never collide. That part took us a week; it has not caused a single problem since.

Leak test cell with two KUKA robots
Two KUKAs, one carriage and the 7th-axis rail we designed ourselves.
03

Seal the enclosure before you trust a helium reading

Helium is very light and disperses instantly in an air current. Measure on an open line and helium drifting over from the next station shows up as a “leak” on your product, or a real leak gets swept away by the draught. We sealed the test stations and set up controlled air circulation. That detail made more difference than the detector itself.

04

Finding the leak is not enough; where you record it matters

When the system finds a leak, it marks the joint on the product’s 3D model: which station, which joint, which robot, what time. The record is not just for that one product; within weeks you can see, model by model, which brazed joints keep causing trouble. With that table, the quality team began improving the brazing process itself, which is the real point of testing.

We realised late that the most expensive asset in the project was the point list. Robots, cameras and detectors can be bought; that list can only be built on site, together with the product.
05

What would we do differently today?

  • We would start golden-sample calibration on day one and skip the weeks of trial and error.
  • We would write enclosure sealing and air circulation into the project scope from the outset; adding them later is expensive.
  • On a line with more than 55 models, automatic model recognition is a must; manual selection means manual errors.
Daikin leak-testing line

The project behind this post

Daikin leak-testing line

Daikin

View the project

Wrestling with a similar problem?

What we write comes from what we see on the shop floor. Tell us about your line and we’ll work out together where to start.